Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Braz. j. med. biol. res ; 54(9): e10220, 2021. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1249341

RESUMEN

Necrotizing enterocolitis (NEC) is a common condition in preterm infants. The risk factors that contribute to NEC include asphyxia, apnea, hypotension, sepsis, and congenital heart diseases (CHD). The objective of this study was to evaluate the association between the treatment (surgery or drainage) and unfavorable outcomes in neonates with NEC and congenital heart diseases (NEC+CHD). A 19-year retrospective cohort study was conducted (2000-2019). Inclusion criterion was NEC Bell II stage. Exclusion criteria were associated malformation or genetic syndrome and those who did not undergo echocardiography or had a Bell I diagnosis. We included 100 neonates: NEC (n=52) and NEC+CHD (n=48). The groups were subdivided into NEC patients undergoing surgery (NECS, n=31), NEC patients undergoing peritoneal drainage (NECD, n=19), NEC+CHD patients undergoing surgery (NECCAS, n=21), and NEC+CHD patients who were drained (NECCAD, n=29). Multivariate analysis was performed to estimate the relative risk of death and the length of stay. Covariates were birth weight and gestational age. The group characteristics were similar. The adjusted relative risk of death was higher in the drainage groups [NECD (Adj RR=2.70 (95%CI: 1.47; 4.97) and NECCAD (Adj RR=1.97 (95%CI: 1.08; 3.61)], and they had the shortest time to death: NECD=8.72 (95%CI: 3.10; 24.54) and NECCAD=5.32 (95%CI: 1.95; 14.44). We concluded that performing primary peritoneal drainage in neonates with or without CHD did not improve the number of days of life, did not decrease the risk of death, and was associated with a higher mortality in newborns with NEC and clinical instability.


Asunto(s)
Humanos , Recién Nacido , Lactante , Enterocolitis Necrotizante/complicaciones , Cardiopatías Congénitas/cirugía , Cardiopatías Congénitas/complicaciones , Brasil/epidemiología , Recien Nacido Prematuro , Estudios Retrospectivos
2.
Braz. j. med. biol. res ; 52(7): e8585, 2019. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1011588

RESUMEN

Atelectasis and inadequate oxygenation in lung donors is a common problem during the retrieval of these organs. Nevertheless, the use of high positive end-expiratory pressure (PEEP) is not habitual during procedures of lung retrieval. Twenty-one Sprague-Dawley male consanguineous rats were used in the study. The animals were divided into 3 groups according to the level of PEEP used: low (2 cmH2O), moderate (5 cmH2O), and high (10 cmH2O). Animals were ventilated with a tidal volume of 6 mL/kg. Before lung removal, the lungs were inspected for the presence of atelectasis. When atelectasis was detected, alveolar recruitment maneuvers were performed. Blood gasometric analysis was performed immediately. Finally, the lungs were retrieved, weighed, and submitted to histological analysis. The animals submitted to higher PEEP showed higher levels of oxygenation with the same tidal volumes PO2=262.14 (PEEP 2), 382.4 (PEEP 5), and 477.0 (PEEP 10). The occurrence of atelectasis was rare in animals with a PEEP of 10 cmH2O, which therefore required less frequent recruitment maneuvers (need for recruitment: PEEP 2=100%, PEEP 5 =100%, and PEEP 10=14.3%). There was no change in hemodynamic stability, occurrence of pulmonary edema, or other histological injuries with the use of high PEEP. The use of high PEEP (10 cmH2O) was feasible and probably a beneficial strategy for the prevention of atelectasis and the optimization of oxygenation during lung retrieval. Clinical studies should be performed to confirm this hypothesis.


Asunto(s)
Animales , Masculino , Ratas , Atelectasia Pulmonar/rehabilitación , Intercambio Gaseoso Pulmonar/fisiología , Volumen de Ventilación Pulmonar/fisiología , Respiración con Presión Positiva/métodos , Trasplante de Pulmón/métodos , Atelectasia Pulmonar/fisiopatología , Ratas Sprague-Dawley , Modelos Animales
3.
Braz. j. med. biol. res ; 47(3): 259-264, 03/2014. tab
Artículo en Inglés | LILACS | ID: lil-704627

RESUMEN

This study evaluated whether the use of continuous positive airway pressure (CPAP) in the delivery room alters the need for mechanical ventilation and surfactant during the first 5 days of life and modifies the incidence of respiratory morbidity and mortality during the hospital stay. The study was a multicenter randomized clinical trial conducted in five public university hospitals in Brazil, from June 2008 to December 2009. Participants were 197 infants with birth weight of 1000-1500 g and without major birth defects. They were treated according to the guidelines of the American Academy of Pediatrics (APP). Infants not intubated or extubated less than 15 min after birth were randomized for two treatments, routine or CPAP, and were followed until hospital discharge. The routine (n=99) and CPAP (n=98) infants studied presented no statistically significant differences regarding birth characteristics, complications during the prenatal period, the need for mechanical ventilation during the first 5 days of life (19.2 vs 23.4%, P=0.50), use of surfactant (18.2 vs 17.3% P=0.92), or respiratory morbidity and mortality until discharge. The CPAP group required a greater number of doses of surfactant (1.5 vs 1.0, P=0.02). When CPAP was applied to the routine group, it was installed within a median time of 30 min. We found that CPAP applied less than 15 min after birth was not able to reduce the need for ventilator support and was associated with a higher number of doses of surfactant when compared to CPAP applied as clinically indicated within a median time of 30 min.


Asunto(s)
Femenino , Humanos , Recién Nacido , Masculino , Embarazo , Presión de las Vías Aéreas Positiva Contínua , Salas de Parto , Recién Nacido de muy Bajo Peso/fisiología , Surfactantes Pulmonares/uso terapéutico , Síndrome de Dificultad Respiratoria del Recién Nacido/prevención & control , Extubación Traqueal , Brasil , Mortalidad Hospitalaria , Hipertensión/diagnóstico , Intubación Intratraqueal , Tiempo de Internación , Bienestar Materno , Diagnóstico Prenatal , Respiración Artificial
4.
Braz. j. med. biol. res ; 46(10): 892-896, 24/set. 2013. tab
Artículo en Inglés | LILACS | ID: lil-688560

RESUMEN

The objective of this study was to determine the feasibility of the use of continuous positive airway pressure installed prophylactically in the delivery room (DR-CPAP), for infants with a birth weight between 500 and 1000 g in settings with limited resources. During 23 months, infants with a birth weight between 500 and 1000 g consecutively received DR-CPAP. A total of 33 infants with low birth weight were enrolled, 16 (48.5%) were females. Only 14 (42.4%) received antenatal corticosteroids and only 2 of those 14 (14.3%) infants weighing 500-750 g were not intubated in the delivery room, and apnea was given as the reason for intubation of these patients. Of the 19 infants in the 751-1000 g weight range, 9 (47.4%) were intubated in the delivery room, 6 due to apnea and 3 due to respiratory discomfort. For DR-CPAP to be successful, it is probably necessary for preterm babies to be more prepared at birth to withstand the respiratory effort without the need for intubation. Antenatal corticosteroids and better prenatal monitoring are fundamental for success of DR-CPAP.


Asunto(s)
Femenino , Humanos , Recién Nacido , Masculino , Presión de las Vías Aéreas Positiva Contínua , Recién Nacido de muy Bajo Peso , Síndrome de Dificultad Respiratoria del Recién Nacido/terapia , Brasil , Salas de Parto , Países en Desarrollo , Estudios de Factibilidad , Recien Nacido Prematuro
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA